Home / product / Vacuum Components / Vacuum Pump / Dry Vacuum Pump LR/HR/UR Series
Model | LR/HR 60 | LR/HR 90 | LR 180 | LR 421 | LR 421-T | UR 421-T | LR/HR 300 | LR/HR 600 | UR 600 | LR/HR 1200 | UR 1200 | ||
Pump | DRP | LR/HR 60 | LR/HR 90 | LR 180 | LR 421 | LR 421-T | UR 421-T | LR/HR 60 | LR/HR 90 | UR 90 | LR/HR 90 | UR 90 | |
MBP | - | PRC-003A | PRC-006A | PRC-012A | |||||||||
Max. pumping speed | m3/h | 50Hz | 62 | 112 | 183 | 440 | 440 | 410 | 359 | 653 | 653 | 1012 | 1012 |
60Hz | 80 | 126 | 237 | 365 | 701 | 1051 | |||||||
L/min | 50Hz | 1030 | 1860 | 3100 | 7333 | 7333 | 6833 | 5980 | 10900 | 10883 | 16900 | 16867 | |
60Hz | 1333 | 2100 | 3950 | 6080 | 11700 | 17500 | |||||||
Ultimate pressure | Pa | 5.0 | 0.67 | ||||||||||
Max. inlet pressure | Atmospheric pressure * | ||||||||||||
Max. exhaust pressure | 1.0 to Atmospheric pressure | ||||||||||||
Inlet diameter (type CE) | VG50 (KF40) | VG80(KF50) | VG100 | VG80(KF80) | VG100(KF100) | ||||||||
Outlet diameter | KF40 | VG50 | KF40 | ||||||||||
DRP: Rotor blade surface treatment | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ||
MBP: Rotor blade surface treatment | – | – | – | – | – | – | ○ * | ○ * | ○ | ○ * | ○ | ||
Weight | kg | 180 | 245 | 335 | 415 | 251 | 371 | 403 | |||||
Power | Three phase | VAC (Hz) | 200(50/60), 220(60) | 180~240/380~440(50/60) | 200(50/60), 220(60) | ||||||||
Current | At ultimate pressure | A | 6.9/7.1 | 11.2 | 18.9 | 20.8 | 23 | 7.0/7.8 | 12.3/12.9 | 16.4 | 13.7/15.4 | 18.9 | |
At max. load | A | 7.0/7.3 | 11.8 | 20.6 | 48.5 | 52.5 | 9.6/8.1 | 19.0/13.8 | 17.3 | 24.2/18.9 | 22.4 | ||
Cooling water Supply pressure | MPa | 0.1 to 0.3 | 0.2 to 0.5 | 0.1 to 0.3 | |||||||||
Cooling water In/Out differrence pressure | MPa | >0.1 | >0.2 | >0.1 | |||||||||
Cooling water Flow rate | L/min | >5.0 | >4.0 | >5.0 | >5.0 | ||||||||
N2 gas | Supply pressure | MPa | 0.1 ~ 0.5 | ||||||||||
Regu-lated pressure | MPa | 0.05 ~ 0.1 | |||||||||||
N2 purge | Shaft purge | SLM | 5 | ||||||||||
Gas ballast | SLM | 0~45 | None *1 | 0~45 | 0~195 | 0~45 |
*Please specify voltage at the time of ordering.
*LR pump designed for low operating temperature of the pump body. The HR is for high temperature pump body operation. While the UR series is for Ultra High pump body temperature.
*The HR300, HR600, HR1200,UR600,UR1200,UR1800 and UR3601-TT models should all be operated below 200Pa (1.5 Torr).
*The LR3601-R/TR/TTR is an improved exhaust performance model in the high-pressure area.
*〇=with ×=with out
*MBP of LR300, LR600, LR1200, LR1800, can choose the existence of a surface treatment.
*Additionally, a pump with gasballast use is possible to quote. Please contact us for the selection and quotation.
■Silencer (Option)
Model | Material | Surface treatment | Weight (kg) | Flange Connection |
RS-01 | SUS304 | GBB treatment | 4.1 | NW40 |
RS-02 | SUS304 | GBB treatment | 8.3 | NW40 |
RS-03 | SUS304 | Polished plate | 12.5 | NW50 |
■Acceptable Table
Kit type | Agreement | Clamp | Outer ring | Connection Flange | Stay |
RS-01 kitA | LR60,LR90,LR300 | 1 | 1 | – | – |
RS-01 kitB | LR600,LR1200 | 2 | 2 | 1 | 1 |
RS-02 kitA | LR180(LR60,LR90,LR300) | 2 | 2 | 1 | 1 |
RS-02 kitB | LR1800(LR600,LR1200) | 2 | 2 | 1 | 1 |
RS-03 kitA | LR421(-T) | 1 | 1 | 1 | 1 |
RS-03 kitB | LR3601(-T/TT/R/TR/TTR) | 3 | 3 | 1 | 1 |
29/11/100 Le Duc Tho Street, Ward 7, Go Vap District Ho Chi Minh City, Vietnam