Home / product / Vacuum Components / Vacuum Valves / Vacuum Valves VLH Series
Model | VLH-SB |
Maximum allowable differential pressure on valve plate (Positive pressure/counter pressure) MPa | 0.10 |
Maximum allowable differential pressure in opening direction (Positive pressure/counter pressure) MPa | 0.10 |
Plate seal | O-ring |
Feedthrough | Bellows |
Actuation | Manual |
External leak rate*1 Pa・m3/s | ≦1.0E-10 |
Internal leak rate*1 Pa・m3/s | ≦1.0E-10 |
Operating pressure range (absolute pressure) Pa | Atm. ~ 1.0E-6 |
Bakeout temperature (when stopping)*2 ℃ | Body:150*3, actuation:70 |
Operating ambient temperature ℃ | 5~70 |
Fluid temperature ℃ | 5~70 |
Heating & cooling speed ℃/h | ≦30 |
Operating ambient | Non-corrosive |
Fluid | Non-corrosive |
Compressed air to cylinder MPaG | ー |
Warranted operation cycle*4 | 10,000 |
Orientation | No limitation |
Position indicator | ー |
Material of major parts (Vacuum side) | Stainless steel 304 |
Material of major parts (Atmosphere side) | Stainless steel 304, Aluminum-6061 (anodized aluminum) |
Bellows material | Stainless steel 316L |
Seal material (Vacuum side) | FKM |
Grease (Vacuum side) | Any grease is not used |
Attachment for lifting | None*5 |
RoHS | Complied |
*1 Leak rate does not include permeation in O-ring. External leak during opening and closing is not regulated in the case of O-ring shaft seal feedthrough.
*2 Do not open and close during bakeout.
*3 Regarding to VLP-MB abd VLH-MB, maximum body bakeout temperature in opening position: 200?C (392F) and in closing position: 150?C (302F).
*4 See instruction manual for detail.
*5 Lifting attachment is included for VLP-SA350JH (Eyebolt M12 x 2pcs).