Home / product / Vacuum Components / Process Gas Monitor
Model | CGM2-051 | CGM2-052 |
Mass filter type | Quadrupole | |
Mass range | 1 to 50 amu | |
Resolution | M/ΔM=1M (10% P.H.) | |
Detector type | Faraday cup (FC) | EM Tube (SEM) / Faraday cup (FC) |
Sensitivity | 10?? A/Pa | SEM:10?? A/Pa |
1.33×10?? A/Torr | SEM:1.33×10?? A/Torr | |
10?? A/mbar | SEM:10?? A/mbar | |
Minimum detectable partial pressure | 1×10?? Pa | SEM:1×10-10 Pa |
7.5×10-10 Torr | SEM:7.5×10-13 Torr | |
1×10?? mbar | SEM:1×10-12 mbar | |
Maximum operating pressure | FC:2 Pa | FC:2, SEM:1×10?? Pa |
FC:1.5×10?? Torr | FC:1.5×10?? SEM:7.5×10?? Torr | |
FC:2×10?? mbar | FC:2×10?? SEM:1×10?? mbar | |
Linearity | 1Pa | |
7.5×10?? Torr | ||
1×10?? mbar | ||
Filament | lr/Y?O? | |
Ionzing voltage | 40eV | |
Emission current | 0.1mA/0.4mA | |
Degas | Electron bombard type 300V,5mA | |
Total pressure function | Capable | |
One Click function | Capable/He/H?O/N?/O?/Any gas | |
One Click leak test function | Capable | |
Power input | DC24V ±10% 50W | |
Weight(Sensor unit/sensor) | 2.1kg/0.44kg | 2.2kg/0.44kg |
Maximum sensor operating temperature | 120℃(248?) | |
Maximum bakeout temperature (electronics removed) | 250℃(482?) | |
Operating temperature range | 10 to 40℃ (50 to 104?) | |
Operating humidity range | 15 to 80% (not condensing) | |
IP rating | IP30 (sensor unit) | |
Power connector | MSTB2.5/3-STF-5.08 | |
Communication interface | RS232C/RS485 (with option) | |
External input/output connector | D-sub15-pin (M2.6 screw) | |
Communication connector | RJ-45 | |
External input/output signal | Analog input(0 to 10V)×2,External interlock input(pressure protection)×1,Partial pressure setpoint output ×2(fault,alarm),Total pressure setpoint output ×1 | |
Software | Qulee QCS Ver. 4.0 later (Windows 8/10) | |
Standard accessories | Power connector,Communication cable(3m long),Software(install CD),Instruction manual(clean paper) | |
Optional accessories (Cf. Qulee optional catalogue) | QIP(Auto-measuring package spec.),Communication cable(5m,10m,15m long),AC Power adapter,USB-LAN adapter,Swinting hub(8 ports or 16ports),Input / output connecter,Jacket heater,Carry case | |
Applicable standard | CE |
※When there is no RS232C port in PC,please purchase USB/RS232C micro converter of option.
※Please prepare an AC/DC power supply or please purchase the AC/DC adapter of an option.
Resolution M/△M=1M(10% P.H.)
Model | BGM2-101 | BGM2-201 | BGM2-102 | BGM2-202 |
Mass filter type | Quadrupole | |||
Mass range | 1~100 amu | 1~200 amu | 1~100 amu | 1~200 amu |
Detector type | Faraday cup | EM tube Faraday cup | ||
Sensitivity | 10-7A/Pa | 4A/Pa | ||
Minimum detectable partial pressure | 10-8Pa | 10-12Pa | ||
Maximum operating pressure | 1x10-2Pa | |||
Total pressure function | Capable/10-2 ~ 10-5Pa | |||
One Click function | Capable /He/H2O/N2/O2/Any gas | |||
One Click leak test function | Capable | |||
Power input | DC24V±10% 50W | |||
Maximum sensor operating temperature | 120℃ (248?) | |||
Maximum bakeout temperature (electronics removed) | 250℃ (482?) | |||
Operating temperature range | 10 to 40℃ (50 to 104?) | |||
Software | Qulee QCS Ver.4.0 later (Windows 7/8/10) | |||
Applicable standard | CE |
ULVAC's new "Qulee HGM2" residual gas analyzer series with revolutionary simplicity of use.
Offers highest sensitivity of all models at 2.5 × 10 -6A/Pa, Qulee HGM2.
Can meet the needs of various R&D and other vacuum system proce ss monitoring.(Ethernet compatible)
Model | HGM2-202 | HGM2-302 | ||
Mass filter type | Quadrupole | |||
Mass range | 1 ~ 200 amu | 1 ~ 300 amu | ||
Resolution | M/ ΔM=1M(10% P.H.) | |||
Detector type | Faraday cup | SEM | Faraday cup | SEM |
Sensitivity | 2.5×10?? A/Pa | 4 A/Pa | 2.0×10?? A/Pa | 4 A/Pa |
3.3×10?? A/Torr | 533 A/Torr | 3.3×10?? A/Torr | 533 A/Torr | |
2.5×10?? A/mbar | 400 A/mbar | 2.5×10?? A/mbar | 400 A/mbar | |
Minimum datectable partial pressure | Approx. 10?? Pa | Approx. 10-13Pa | Approx. 10?? Pa | Approx. 10-13Pa |
Approx. 7.5×10-12 Torr | Approx. 7.5×10-16 Torr | Approx. 7.5×10-12 Torr | Approx. 7.5×10-16 Torr | |
Approx. 1×10-11 mbar | Approx. 1×10-12 mbar | Approx. 1×10-11 mbar | Approx. 1×10-12 mbar | |
Maximum operating pressure | 1×10??Pa | |||
7.5×10?? Torr | ||||
1×10?? mbar | ||||
Filament | lr / Y?O?, 2pcs | |||
Ionizing voltage | 25 ~ 70 eV(defalut:70eV) | |||
Emission current | 0.1mA/0.5mA/1.0mA(default:0.5mA) | |||
DEGAS | Electron bombard type 330V, 5mA | |||
Total pressure function | Capable / 10?? ~ 10??Pa | |||
"One Click" function | Capable / He/H?O/N?/O?/Any gas | |||
"One Click" leak test function | Capable | |||
Power input | DC24V±10% 50W | |||
Weight(sensor unit / sensor) | 2.4kg/0.81kg | |||
Maximum sensor operating temperature | 250℃(482?) | |||
Maximum bakeout temperature (elsectronisc removed) | 300℃(572?) | |||
Operating temperature range | 10 to 40℃(50 to 104?) | |||
Operating humigity range | 15 ~ 80%(not condensing) | |||
IP rating | IP30(sensor unit) | |||
Power connector | MSTBV2.5/3-STF-5.08 | |||
Communication interface | Ethernet compatible | |||
External input / output connector | D-sub15-pin (M2.6 screw)(eith option) | |||
Communication connector | RJ45 | |||
External input / output signal | Analog input (0 to 10V)×2,External interlock input (pressure protection)×1,Error output ×1(FIL,SEM,RF,fault),Partial pressure setpoint output ×2(fault,alarm),Total pressure setpoint output ×1 | |||
Software | Qulee QCS Ver.4.0 later (Windows 7/8/10) | |||
Standard accessories | Power connector,Communication cable (3m long),Software (install CD),Instruction manual (CD) | |||
Option accessories (cf. Qulee optional catalogue) | Communication cable (10,15,20,30,50m long), AC power adapter, USB-LAN adapter, Switing hub(8ports or 16ports), Input / output connector, Jacket heater, Carry case | |||
Applicable standard | CE |
※Please prepare an AC/DC power supply or please purchase the AC/DC adapter of an option.
Model | RGM2-202 | RGM2-302 |
Sensor | ||
Mass filter type | Quadrupole | |
Mass range | 1 to 200 amu | 1 to 300 amu |
Resolution | M/△M=1M (10%P.H.) | |
Detector type | SEM/Faraday cup | |
Sensitivity | 1×10-3 A/Pa | |
1.33×10?? Torr | ||
0.1A/mbar | ||
minimum detectable partial pressure (inside analyzer tube) | 1×10-10 Pa | |
7.5×10-13 Torr | ||
1×10-12 mbar | ||
Ion source | Closed ion source utilizing a magnetic field | |
Filament | Ir/Y2O? coated V type, 1pc | |
Ionization voltage | 20 to 70 eV | |
Emission current | 10μA | |
DC amplification range | 1×10-5 to 1×10-12 A | |
Maximum bakeout operating temperature | 120℃ (248?) | |
Differential pumping system | ||
Gas inlet value | Conductance value with 3 different gas inlet modes (VPC-070) | |
Max. sampling pressure | 13kPa | |
97.5Torr | ||
130mbar | ||
Differential pumping system | With intermadiate port and gas purge port | |
Turbo molecular pump | 67L/s:N? | |
Fore pump | DIS090 | |
Pirani vacuum gauge | SW1-1 | |
Ionization vacuum gauge | GI-M2 | |
Weight | Pumping system:57kg / Controller:38kg | |
Utility | ||
Power supply | AC100V 15A | |
Compressed air | Dry N2:0.4 to 0.7MPa (Φ6 one-touch joint) | |
Dry N2:3×10?? to 5.25×10?? Torr (Φ6 one-touch joint) | ||
Dry N2:4 to 7 mbar (Φ6 one-touch joint) | ||
Control unit | ||
"One Click" function | Capable / He/H2O/N2/O2/Any gas | |
External I/O and other | Analog input×2 (0 to 10V) | |
Set-point output×2 (fault,alarm) | ||
External interlock | ||
Others | ||
Baking heater | Tape heater | |
Stand | Standard | |
Sensor unit (Control box cable) | 5m | |
Interface | Ethernet | |
Software | Qulee QCS Ver.4.0 later(Windows 7/8/10) | |
Option | PC |
Qulee main body | Select from Qulee BGM2-101/102/201/202, HGM2-302 | |
Max sampling pressure | Select from atmospheric pressure 3000Pa/500Pa/100Pa/10Pa/1Pa | |
Select from atmospheric pressure 22.5Torr/3.75Torr/0.75Torr/7.5×10??Torr/7.5×10??Torr | ||
Select from atmospheric pressure 30mbar/5mbar/1mbar/0.1mbar/1.0×10??mbar | ||
Gas induction (500 to 1Pa type/3.75 to 7.5×10??Torr type/5 to 1.0×10??mbar type) | Manual bellows valve・Flange ICF070 | |
Atmospheric pressure type | Please contact us for the detailed specification on separately. | |
Pump unit Desktop YTP (YTP70A-D) | TMP | Pumping speed 70L/s(N?) |
Dry pump | Pumping speed 20L/min | |
Ultimate pressure | Below 10??Pa (7.5 × 10?? Torr, 1.0 × 10?? mbar) (value after TMP bale out) | |
Input voltage | Single phase AC100 ~ 240V, 300W | |
Software | Qulee QCS Ver.4.0 (Windows 7/8/10) | |
Optional accessories | Ioniation gauge package (SH-1, Sensor head cable 2m,Cross tube,Bolts,Gaskets),Carry cart,USB-LAN adapter,Switching hub(8 ports or 16 ports) |
29/11/100 Le Duc Tho Street, Ward 7, Go Vap District Ho Chi Minh City, Vietnam
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |